Hygrometric probe for EMS economizers

The Deltech energy savers (EMS / E8) are equipped with a new pressure dew point measurement probe.

Deltech energy savers (EMS / E8)

This probe is positioned in the lower part of the dryer, behind the front panel.

It is supplied by a compressed air sampling line taken from the dryer outlet, filtered to 1 micron, and is fitted with an isolation valve.

The sweep rate on the probe is now calibrated at the factory using a capillary to facilitate commissioning operations.